Powercom Imperial Digital 3000VA Line Interactive UPS
- Product Code: PCM-IMD-3000AP
- Brand: Powercom
Description
Powercom Line Interactive UPS - Imperial Digital series (3000VA)
The Powercom Imperial Digital UPS with AVR (Automatic Voltage Regulation) will provide protection against surges, spikes and lightning strikes and battery backup in case of power failure. The unit features a digital LED indicator which displays the output voltage and battery level.
Product Features:
- Elegant design with digital LED indicator displaying battery capacity and output voltage
- Built-in automatic boost and buck AVR (Auto voltage AVR)
- Simulated sine wave output waveforms
- Green mode setting for energy saving
- Automatic self-diagnostic and alarm warnings
- Surge, short circuit, and overload protections
- Discharge and overcharge protection
- Scheduling shutdown & reboot function
- Events recorder of power incidents
IMPORTANT WARRANTY NOTICE:
The LEAD ACID Batteries contained within this UPS device are rated to last 150-200 cycles. The life cycle refers to the battery being depleted completely and charged back up to 100% capacity. We strongly recommend not to deplete the battery’s charge below 50% as this could damage the battery’s lifecycle and will result in the battery’s ability to function normally for only 2 – 3 months.These batteries are not designed to keep devices powered during an entire load shedding schedule, but rather to enable the user to have time to shut down devices (PC’s, Laptops) safely. Therefor during a power outage and loadshedding schedule we recommend shutting down the UPS after all connected devices have been shut down safely.
Specification
UPS Specs | |
Input Voltage | 100V / 110V / 120V ±25% 220V / 230V / 240V ±25% |
---|---|
Input Frequency | 50Hz / 60Hz ±10% auto sensing |
Output Connections | 6 x IEC Sockets |
Output Voltage (Backup mode) | 100V / 110V /115V / 120V (±5% on battery) 220V /230V / 240V (±5% on battery) |
Output Frequency (Backup mode) | 50Hz / 60Hz ±1% |
Output Waveform | Simulated sine wave |
Output Transfer Time | 2 to 4 millisecond including detection time (typical) |
Automatic Voltage Regulator (AVR) | AVR with 1 step boost and 1 step buck |
Overload Protection | Auto power off if overload exceeds 110% of nominal at 60 seconds; 130% at 3 seconds |
Unit Input Protection | Fuse or overload & short circuit protection |
Tele-communication Protection | RJ45 |
Alarm | Buzzer beeps under backup mode, battery low, battery charging fault, and overload |
Battery Type | Sealed, maintenance-free lead acid battery |
Typical Recharge Time | 6 hours to 90% |
Battery Quantity | 12V 9Ah x3 |
Battery Protection | Automatic diagnostics, over-discharge and short circuit protection |
Display | Digital LED - Indicates output voltage and battery levels |
Audible Noise | < 40dBA (1m from surface) |
Ambient Operation | Max elevation at 2000m, 0 to 40C, 0 to 95% humidity (non-condensing) |